Data List
|
|
|
||
|
|
|
General Property Data for Everflon™ PFA 403
| Properties | Test Method&Unit | Typical Value |
| Specific Gravity | ASTM D792 | 2.15 |
| Critical Shear Rate, 372 °C (702 °F) | 1/s12 | |
| Flexural Modulus |
ASTM D790/ MPa (psi) 23 °C (73 °F) 250 °C (482 °F) |
625 (90,000) 69 (10,000) |
| MIT Folding Endurance (0.20 mm, 8 mil film) | ASTM D2176 Cycles | 500,000 |
| Hardness Durometer | ASTM D2240 | D55 |
| Dielectric Strength, Short Time, 0.25 mm (0.010 in) | ASTM D149 kV/mm | >80 |
| Dielectric Constant, 1 MHz (106Hz) | ASTM D150 | 2.0 |
| Dissipation Factor, 1 MHz (106Hz) | ASTM D150 | <0.0002 |
| Volume Resistivity | ASTM D257 / ohm·cm | 1018 |
| Water Absorption, 24 hr | ASTM D570 % | <0.01 |
| Weather and Chemical Resistance | Outstanding | |
| Limiting Oxygen Index | ASTM D2863 % | > 95% |
| Continuous Service Temperature | °C (°F) | 260 (500) |
| Flammability Classification | UL 94 | V-0 |
| Typical Applications |
| Applications for Everflon™ PFA 403 include extruded tubing for use in handling aggressive fluids at high pressures; chemical linings for pipes used in the chemical processing industry; film for high flex service; and traditional extruded, injection-molded, or blowmolded articles requiring the unique performance of Everflon™ |
|
Processing Guide |
|
Everflon™ PFA 403 can be processed by conventional melt extrusion, and by injection, compression, and transfer molding processes. High melt strength and heat stability permit the use of relatively large die openings and high temperature draw-down techniques that increase production rates. Reciprocating screw injection molding machines are preferred.
Corrosion-resistant metals should be used in contact with molten fluoroplastic resin. Extruder barrel should be long, relative to diameter, to provide residence time for heating the resin to approximately 390 °C (730 °F).
|
| Precaution |
| Equipment used to process at melt temperatures should be provided with local exhaust ventilation (LEV) to completely remove all fumes and vapors from the processing area. In addition, care should be exercised to avoid the contamination of cigarettes and other forms of smoking tobacco when using fluoroplastic resins. Before processing any fluoroplastics, read the Material Safety Data Sheet. |
| Package |
|
The properties of Everflon™ PFA resin are not affected by storage time. Ambient storage conditions should be designed to avoid airborne contamination and water condensation on the resin when it is removed from containers. Everflon™ PFA is supplied as pellets and is available in 25-kg multilayer bags with an integral polyethylene liner. |
| Everflon™ PFA 403 for The World Advanced Market. | |||||||||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Keep exploring Everflon™. |
|||
| Polymer of Dreams | |||
![]() |
![]() |
![]() |
|
![]() |
![]() |
||
![]() |
![]() |
![]() |
CREATING A BETTER WORLD THROUGH THE POWER OF OUR FLUOROPOLYMERS
Our responsible fluoropolymers helps build a sustainable future for all.
|
|
FLUOROPOLYMERS IN ACTION
Everflon™ is creating a better world through the power of our chemistry. |
![]() |
![]() |
|
![]() |
![]() |
![]() |
|
![]() |
![]() |
VIEW ALL FLUOROPOLYMERS APPLICATION --> |
|
| Everflon™ safety and the environment. | |||||
| Learn more in our Product Environmental Report | |||||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
If you have any questions, feedback or comments, please fill out the form below and we will reply you back as soon as possible.